There are many kinds of Atlas air compressors, and each type of air compressor has different uses. What misunderstandings do you need to pay attention to when choosing Atlas air compressors?In this way, the pit can be avoided when the air compressor is purchased。

1. Consider the level of exhaust pressure and the size of exhaust volume

According to the national standard general purpose aerodynamic compressor exhaust pressure is 0.7MPa (7 atmospheres), the old standard is 0.8MPa (i.e. 8 atmospheres)。Because pneumatic tools and wind machinery are designed to work at a pressure of 0.4Mpa, so the working pressure of the air compressor can fully meet the requirements。If the user's compressor is greater than 0.8MPa is generally special production, and forced pressurization can not be adopted to avoid accidents。
The size of the exhaust volume is also one of the main parameters of the air compressor, and the selection of the air volume of the compressor should match the exhaust volume required by itself, and leave a 10% margin。If the air consumption is large and the air compressor displacement is small, the air compressor exhaust pressure will be greatly reduced when the air tool is started, and the air compressor exhaust pressure can not be driven。Of course, the blind pursuit of large displacement is also wrong, because the larger the displacement of the compressor with the larger the motor, not only the price is high, but also a waste of purchase funds, the use of electricity will also waste energy。
In addition, when selecting the exhaust volume, it is also necessary to consider the peak consumption and the usual consumption and the trough consumption。The usual way is to obtain a larger displacement of smaller air compressors in parallel, with the increase of gas consumption, and turn on one by one, which is not only good for the grid, but also can save energy (with several open several), and there is a backup machine, not due to the failure of a machine caused by the whole line to stop production。
2, consider the occasion and conditions of gas use
The occasion and environment of gas use is also an important factor in choosing the type of compressor, for example, if the gas site is small, it should be selected vertically。Such as ship, car;If the use of gas to make long-distance changes (more than 500 meters), should consider mobile;If the use of the occasion can not be powered, you should choose diesel driven type;
If there is no running water, you must choose air-cooled。In the two cooling methods of air cooling and water cooling, users often have the illusion that water cooling is better and that it is fully cooled, but it is not。In small compressors, both at home and abroad, air-cooled type accounts for more than 90%。
In design, air cooling is simple, and no water source is needed when using。Water-cooled type has its fatal shortcomings, first of all must have a complete water supply system, large investment;Second, the water-cooled cooler life is short;Third, it is easy to freeze the cylinder in the northern winter;Fourth, a lot of water is wasted in normal operation。
3, consider the quality of compressed air

The compressed air produced by the general air compressor contains a certain amount of lubricating oil, and a certain amount of water, some occasions are forbidden oil and water, then not only to pay attention to the compressor selection, if necessary to increase the auxiliary device。There are two solutions:


(1) Choose non-lubricated compressor。The compressor cylinder is basically oil-free, and its piston ring and packing are generally polytetrafluoroethylene。This machine also has its disadvantages, the first is poor lubrication, high failure rate;In addition, polytetrafluoroethylene is also a harmful substance, such as food, pharmaceutical industry can not be used, and non-lubricated compressor can only be oil-free gas transmission, can not be water-free。
(2) Therefore, the usual practice is to add a primary or secondary purification device or dryer to the air compressor (no matter what kind)。This device can make the compressor air neither oil nor water, so that the oil water content in the compressed air is below 5ppm to meet the process requirements。
4. Consider the safety of operation
Air compressor is a machine with pressure work, working with temperature rise and pressure, the safety of its operation should be put in the first place。In addition to the safety valve, the air compressor is also designed with a pressure regulator, the implementation of overpressure unloading double insurance, only the safety valve without the pressure regulator is unreasonable, not only will affect the safety coefficient of the machine, but also reduce the economy of operation (the general function of the pressure regulator is to close the suction valve, so that the machine runs empty)。
2022.10.08
MORE>>
Screw type air compressor control panel role
What role does the screw air compressor control panel play in the air compressor?Let's find out。
1. Basic operation keys:
1、 启动。Start the air compressor under normal working condition。
2、停止。Stop the air compressor under normal working condition
3. Tight stop/reset。This button in an emergency, or in the case of not allowed to start the camera, cut off the AC power, at this time press the "start button" air compressor controller does not respond。Tight stop and fault reset function。
4、 远程。Local switching。Switch between single machine control and joint control
Second, alarm function:
1, air filter blocking alarm
2, oil filter blocking alarm
3, oil and gas separator blocking alarm
4, electrical heavy fault alarm, including program error (prohibited start), host overload (emergency shutdown), heat dissipation fan overload (emergency shutdown)
5, the host temperature is high (emergency shutdown), the exhaust temperature is high (emergency shutdown)
6, cooler temperature alarm, cooler water loss alarm
Third, the role of the indicator:
1, air filter alarm light。When the air filter is blocked or the timing time is up, the air filter alarm light is on。
2, oil filter alarm light。When the oil filter is blocked or the timing time is up, the oil filter alarm light is on
3, oil and gas separator alarm light。When the oil and gas separator is blocked or the timing time arrives, the oil and gas separator alarm light is on
4, when the host is overloaded, the electrical fault indicator is steady on and shut down
5, when the exhaust temperature is high, the exhaust temperature indicator is steady on and shut down
6. Power indicator: When the controller is normally powered, the power indicator is steady on
7, remote control indicator, when the air compressor remote control, the remote control indicator light is on
8. Standby indicator. When other defined faults occur, the standby indicator is steady on
2022.07.29
MORE>>
Three techniques for daily prevention of air compressors

The air compressor is composed of many accessories, each of which is very expensive, and the motor is also counted as one。If the motor is burned during the operation of the air compressor, it will not only cause inconvenience in all aspects, but also cost a lot of money for maintenance。A small series of three ways to maintain air compressors:


First, the motor of the air compressor is prohibited from long-term overload use: this non-standard operation is often encountered in many small and medium-sized enterprises。In the case of long-term operation, it will lead to a rapid decline in the speed of the motor, the current continues to increase under the action of low voltage, the temperature of the motor will gradually rise, if not stopped in time, then the motor of the air compressor will soon have the risk of burning;

Second, when the motor of the air compressor is usually in the working state of vibration or some abnormal sound, it needs to pay attention to, in this case, it must be found out the cause of the motor failure, otherwise it will face the motor burn;
Third, do a good job of regular cleaning and maintenance of the motor, cleaning items include:
1. The motor starting device is an important reason for the motor burning, which needs to be placed in a ventilated environment for a long time and ensure that the rust of each contact is removed.
2, the motor air inlet to ensure a high degree of cleanliness, at least in the surrounding three meters to ensure that there is no arbitrary dust particles。
2022.07.26
MORE>>
Do you know why air compressors should be energy-saving?如下

Some people have analyzed the air compressor, the power consumption of the air compressor is very large, but it can not be used, researchers are also studying energy-saving air compressors, constantly updating equipment, resulting in high energy consumption of air compressors for the following reasons:

1. Low equipment efficiency

Most of the air compressors installed a few years ago are low-energy equipment,The device does not match the terminal properly,Just to meet the basic needs of production;The adjustment mode of air compressor is backward and there is no centralized control,When the gas consumption changes randomly,The air compressor is seriously wasted due to unloading;The gas used by the terminal equipment is unreasonable, the efficiency is low, and the gas used by the equipment is wasted。
2. Unreasonable gas supply pressure
There is no hierarchical planning of gas supply pressure, but simply adopts high pressure gas supply plus mechanical self-operated pressure reducing valve to meet different pressure needs, and a lot of energy is wasted on the valve。In addition, when the demand side gas consumption changes cause random fluctuations in the pipe network pressure, in order to avoid frequent start and stop of the unit, it is necessary to set a wide range of pressure changes, resulting in large fluctuations in the outlet pressure of the air compressor, increasing the operation energy consumption of the air compressor system。
3. Causes of energy waste
High no-load energy consumption
At present, most enterprise compressors are single N cubic, and the compressor starts and stops only N or multiple of N, and the air compressor equipment starts and stops relying on the tradition of manual management。Especially when the gas load changes frequently, the system cannot react quickly, nor can it achieve the fine tuning of the compressor displacement, which forms the no-load of the compressor in the air compressor station。

Under normal circumstances, when the pressure reaches y kg, the air compressor enters the unloading operation state, when the pressure is reduced to x kg, the compressor enters the no-load state, that is, the intake valve is closed so that the motor is in an idling state, and the excess compressed air in the oil pre-separation tank is discharged through the vent valve。Closing the intake valve to make the motor idle although the air compressor does not need to compress the gas for work, the air compressor still needs to drive the screw or piston to do rotary movement in idle, and the power consumption continues to occur。The actual test found that the energy consumption of the air compressor under no-load is as high as 40% ~ 55% of its full load operation。

High climbing energy consumption

Screw compressor has two operating modes, adding, unloading operation mode or no-load, full load operation mode。The loading and unloading control mode makes the pressure of the compressed gas move back and forth between x kg and y kg。x kg is the lowest working pressure value, that is, the lowest pressure (loading pressure) that can ensure the normal operation of the user.。Under normal circumstances, the relationship between x kg and y kg can be expressed by the formula: y kg =x kg +(1+δ), δ is a percentage, its value is roughly between 10% and 25%。The pressure difference is generally more than one kilogram。Through theoretical calculation and practical testing, it is learned that for every 1kg increase in air compressor pressure, energy consumption increases by 5-6%。
It can be seen that in the air compressor under the loading and unloading gas supply control mode, its working pressure is from x to y, and there is an energy consumption of pressure climbing, and there is actually energy waste。At the same time, before the gas above x kg enters the gas terminal, its pressure needs to be reduced by the pressure reducing valve to close to x kg, the higher the pressure, the faster the flow rate, which results in the same working condition, the higher the pressure, the greater the gas consumption。The process is also a waste of energy。
Traditional management

In the use and management of air compressor station, there are two unavoidable contradictions。One is that the enterprise has a clear assessment of the air compressor management personnel, then the air pressure is often not enough or the habit of opening less, which is not conducive to the normal operation of the production line, or the pressure can not meet the requirements of the use of equipment, resulting in an increase in the failure of the gas terminal。One is that there is no clear assessment of air compressor managers, which will lead to more air compressors and high no-load energy consumption of air compressor stations。No matter what kind of management mode, the result will be that the waste of electric energy in the air compressor station will increase, and it is not conducive to safe production。


2022.06.30
MORE>>

Copyright ©2020 Atlas Bolet (Le Le) All rights reserved Keywords: screw air compressor Oil free air compressor air compressor accessories

Technical support:Suzhou Shangyun Network Technology Co., LTD Record number:Shanghai ICP for 16021029

" class="hidden">北美在线